HISTORY Ver 4.61 - added high line density support for SLC PRO2x beamformers - added C3.5/40/128 probe support for SLC PRO2x, PRO4x beamformers - changed gamma, contrast, brightness range - updated help Ver 4.6 - added support for SLC PRO 4X beamformer - added high line density support for SLC PRO 4X and BLCA-1Z beamformers - added rejection control Ver 4.5 - enlarged view area for Echo Blaster Rev.C beamformers - added support for Echo Blaster Rev.C beamformers Ver 4.42 - updated default setting for HL10/40/128 probe (Ultra Scan 128 PC-1Z, BLCA-1Z beamformer) Ver 4.41 - added patch for UT-C3.5R20/64 probe (Echo Blaster 1T/2T beamformer) - added patch for UT-C5.0R20/64 probe (Echo Blaster 1T/2T beamformer) - updated patch for C3.5/60/64 probe (Echo Blaster 1T/2T beamformer) Ver 4.4 - changed TGC value in non-working zone of ultrasound image (Sonic Pro 2 scan-converter only) - changed palette dialog - added support of C3.5/60/64 probe (Echo Blaster 1T/2T beamformer, REV:B) - fixed minor cineloop bug Ver 4.32 - updated default setting for PV8.0/10/128 probe (Ultra Scan 128 PC-1Z scanner/BLCA-1Z beamformer) - updated BIN files for PV8.0/10/128 probe (Ultra Scan 128 PC-1Z scanner/BLCA-1Z beamformer) Ver 4.31 - added support of new PCI controller revision for Sonic Pro 2 scan-converter - removed artifacts on image during TGC control in combination with Sonic Pro 2 scan-converter Ver 4.3 - added support of BLCA-1Z beamformer on new PCI controller revision - added support of PV8.0/10/128 probe with Ultra Scan 128 PC-1Z scanner/BLCA-1Z beamformer Ver 4.2 - added support of new PCI controller revision for Sonic Pro scan-converter Ver 4.12 - changed UT-L7.5/64 probe default setting set for Echo Blaster 1T/2T Rev:B beamformers Ver 4.11 - fixed bug with maximize window command in resolutions 1024*768 and more Ver 4.1 - added support of Echo Blaster 1T/2T/1Z beamformer, REV:B - added support of Sonic Pro 2 scan-converter - added support of BLCA-1Z beamformer Ver 4.09 - added analogue potentiometers control (need SPA-01 device) Ver 4.08 - fixed Echo Blaster series kits/scanners start-up Ver 4.07 - updated presets list Ver 4.06 - fixed cineloop bug (when SPA-01 installed) Ver 4.05 - changed algorithm of mouse operation during measurement - updated help file Ver 4.04 - minimized power consumption after software closing (only for Ultra View 128 PC series scanners / SLC PRO 2X beamformer) Ver 4.03 - improved hardware diagnostics during system start-up Ver 4.02 - added support of Echo Blaster 1Z beamformer - additional information is added to LOG file - improved stability in B+M and M modes Ver 4.0 - added "B+A" and "A" modes - added focuses sets support for compatible beamformers - added H.I.T. (Hard Imaging Tissue) mode for compatible beamformers - added additional presets - added multifrequency control for C3.0/20/64 probe (Echo Blaster series scanners) - added support of Ultra Scan 128 PC-1Z scanner / BLCA-1Z beamformer - added support of UT-C3.5R20/128 probe (Ultra View 128 PC series scanners / SLC PRO 2X beamformer) - added support of CLA3.0/20/96 probe (Ultra View 128 PC series scanners / SLC PRO 2X beamformer) - changed probe frequency control for compatible probes/beamformers - changed start focal zones positions for UT-C3.5R60/64 and UT-L7.5/64 probes (Echo Blaster series scanners) - changed start focal zones positions for HL7.5/40/128 probe (Ultra View 128 PC series scanners / SLC PRO 2X beamformer) - fixed minor bug in presets control - fixed minor bug when main window minimized and AutoFreeze turned on - updated support files Ver 3.82 - updated probes recognition algorithm for systems with 2 probes port Ver 3.81 - improved performance in Windows XP operating system - improved compatibility and stability with non-Intel based computer chipsets Ver 3.8 - added urology measurements - updated help file Ver 3.71 - fixed USB printers bug Ver 3.7 - added "Full screen" option for 1024x768 graphic mode ("Advanced" button) - minor interface changes for 1024x768 graphic mode Ver 3.6 - changed uninstall process - fixed minor bug Ver 3.5 - added AutoFreeze function - improved printing algorithm Ver 3.4 - perfoming measurements are more comfortable and user friendly now - abdominal measurement results now can be viewed, managed, printed and saved with echo images - changed report form - date and time format is based on regional settings now - updated help file - other minor changes and bug fixes Ver 3.3 - added possibility to run software without installed ultrasound hardware - added control of FREEZE foot switch (need SPA-01 device) Ver 3.2 - fixed minor bug printing on HP printers - fixed 2 probe port EXP1-2Z minor bug Ver 3.1 - added negative/positive option ("Advanced" button) - added support of 2 probe port EXP1-2Z by UltraView 128 PC (SLC PRO 2X beamformer) Ver 3.0 - added support of Windows 98/ME/2000/XP operating systems (need to install new scan-converter WDM drivers) - added support of color skins (themes) - changed TGC line style - minor interface changes - fixed minor scan-direction indicator bug in freeze mode - updated help file Ver 2.94 - fixed minor free-hand zoom bug Ver 2.93 - hided zoom controls for non-compatible display adapters Ver 2.92 - added scroll bar in the Presets list - added additional Hot Keys, see help - changed/updated help file Ver 2.91 - added Hot Key for "Advanced" button, "CTRL+A" combination - added Hot Key for "B+B mode" window switching, "W" key - changed/updated help file - improved probe recognition for 2-probe systems - Hospital Name automatic saving/restoring - OEM logo stored in external image file, file logo.bmp Ver 2.9 - replaced image filters - improved refresh rate - set "Powerfull computer" to off by default Ver 2.8 - added support of HC3.5/40/128 probe by SLC PRO 2X beamformer - added "Powerful computer" option ("Advanced" button) - fixed palette bug - increased number of colors in saved image Ver 2.77 - minor DSC hardware changes Ver 2.76 - changed focusing data for HC3.5/60/128 probe and SLC PRO 2X beamformer - probe frequency included in common presets (for multi-frequency probes only) Ver 2.75 - added "Test mode" ("Advanced" button) - updated support files Ver 2.74 - changed interface - fixed minor bugs Ver 2.73 - added possibility to move zoomed image for non-compatible display adapters Ver 2.72 - minor interface changes - added possibility to change scan angle for convex probes Ver 2.71 - added support of SLC PRO 2X beamformer with analog signal enhancement Ver 2.7 - added multi-B mode (thumbnail mode) - updated USI format image while saving (now you can view USI files in IrfanView software) Ver 2.65 - fixed minor M-cursor bug in mirror mode Ver 2.63 - added cineloop information during record mode: current frame/total available frames - added possibility to change sweep mode in M-window ("Advanced" button) Ver 2.62 - improved cineloop control interface - fixed minor cineloop bugs Ver 2.61 - added possibility of direct e-mail sending with image or video attachment - minor interface changes - improved system stability - fixed minor bugs Ver 2.6 - added possibility to assign external viewers/software on viewer button - removed internal viewer - changed/updated help file Ver 2.52 - changed installation dialogs Ver 2.51 - added "x1" button, single mouse click reset zoom to 100% Ver 2.5 - added possibility to save/load ultrasound video to/from disk Ver 2.45 - instead of UT-C3.5R15/64 probe added support of C3.5/20/64 probe. Only for Echo Blaster series beamformers. Ver 2.43 - added support of 6.5CV13 probe for SLC PRO 2X beamformer - "Image Enh" feature included in common presets Ver 2.42 - added support of modified SLC PRO 2X beamformer - added support of HC3.5/60/128 probe for SLC PRO 2X beamformer Ver 2.41 - added support of start-up log file - updated troubleshooting file Ver 2.4 - added support of UT-L7.5/128, UT-C5.0R60/128, EC6.5/10/128 probes for SLC PRO 2X beamformer Ver 2.3 - updated support of power control for SLC PRO 2X beamformer - improved transmit/receive focusing for SLC PRO 2X beamformer - improved image scrolling in "B+M" and "M" modes - improved image quality in "B" mode Ver 2.2 - optimized "Image Enh" feature - added support of SLC PRO 2X beamformer - added support of UT-C3.5R60/128, C4.5/50/128, HL7.5/40/128, PV6.5/10/128 probes for SLC PRO 2X beamformer Ver 2.11 - fixed minor multifocus bug Ver 2.1 - updated help file - fixed compatibility bug Ver 2.01 - fixed minor Cineloop hot key bug Ver 2.0 - added cineloop feature - updated help file Ver 1.72 - added patch for UT-L5.0 probe Ver 1.71 - updated UT-CV5.0R15 probe default settings Ver 1.7 - improved system stability - updated default probes settings Ver 1.6 - fixed minor bug loading BMP file Ver 1.5 - changed probes switching algorithm for 2 probe systems - added support of additional beamformers Ver 1.4 - updated manual "DSC Sonic Pro drivers installation" - fixed minor bug in the "Free Hand Zoom" mode Ver 1.3 - added manual "DSC Sonic Pro drivers installation" - changed default settings for Echo Blaster beamformer Ver 1.2 - improved up to 50% transfer rate via PCI bus - updated help file - fixed bug in B+M mode Ver 1.1 - improved frame rate - fixed minor bugs in multifocus mode Ver 1.0 - released this software * Note regarding Windows XP: A pop-up message will appear (stating the driver is not digitally signed by Microsoft). You will need to acknowledge this message (by clicking OK, not Cancel) to proceed with driver installation. (c) 2004 TELEMED - ultrasound medical systems Internet: http://www.telemed.lt Information e-mail: info@telemed.lt TechSupport e-mail: support@telemed.lt